FORA Diamond GD50
Strips
GDH-FADThe GDH-FAD test strips can eliminate interference from oxygen variation and non-glucose sugar such as maltose and galactose, providing you with the most reliable and accurate results. |
Superior Sip-in Technology
Blood application made easier and faster with a light touch. Supported by our Superior Sip-in (SSI) technology, it allows blood to be easily drawn out onto the absorbent area of the strip even when moving. This reduces the chances of strip wastage and boosts accurate glucose detection.
Lancing
New lancing comfort – smart and simple!
FORA’s lancing comfort device provides a more positive testing experience by minimizing the needle vibration as it penetrates through the skin.
step 1. Sit back and relax
The Diamond GD50 is designed to make glucose testing easier and simpler. No strip coding is required. |
step 2. Perform a control solution test
Insert the test strip to turn on the meter and push the button to mark this test as a control solution test displayed as “QC”. Apply the control solution and compare results with the range printed on the test strip vial. The results displayed on the screen should fall within the range. |
step 3. Perform a blood glucose test
Voice Guide:
Thank you for using this product. Please relax during measurement.Please apply blood to the strip.The blood glucose is xxx milligram per deci-liter.
|
|
|
|
|
step 4. Result interpretation
A symbolic message will be displayed with the test results. It is intended for your reference only. Please consult your doctor for your blood glucose target range.
Should you have any concerns about your blood glucose levels, please consult your doctor immediately.
step 5. Data transmission
Test results can be uploaded via Bluetooth connectivity to devices with iOS/Android as the operating system or via a micro USB connection to a personal computer.
Connect the meter to your computer or TeleHealth gateway with the USB cable. “USB” will be displayed on the screen. New test results will be detected and transmitted automatically. |
Model No. |
Diamond GD50 |
Blood Testing |
.Sample Size: 0.5 μL |
Test Strips |
.Enzyme: GDH-FAD |
Memory Capacity |
.A memory capacity of 450 test results with the date and time |
Universal Tone |
.YES |
Functions |
.4 sets of daily alarms |
Data Transmission |
.RS-232 |
Display |
.Large convex lens |
Portability |
.YES |
Power Source |
.One 1.5V AAA alkaline battery |
Dimensions and Weight |
.104.4mm(L) × 58.0mm(W) × 23.0mm(H) |
Measuring Conditions |
.Storage Condition :-20°C to 60°C below 95% Relative Humidity |
Support & manuals
Find information, manuals. Contact our customer support if you would like our friendly agents to help you resolve an issue.